PneuVest Series - Used at more than 1,500 sites in Wuhan, China and Lombardy, Italy
breaks up mucus
making it thinner
creates mini coughs
in lungs to push out mucus
makes the cilia move
faster to carry mucus to the upper airway
Summary of clinical benefits
- Safe in ICU/post-cardiac surgery
- Increase sputum mobilisation
- Improve pulmonary function
- Cost effectiveness
- Decrease hospitalisations, ICU days
- Decrease antibiotic/oxygen needs
- Effective in a wide range of respiratory diseases
Indications
Patients with:
- asthma, bronchiectasis, pulmonary infection, chronic obstructive pulmonary disease
- the atypical pneumonia, myasthenia gravis, chronic bronchitis
- occupational lung disease, impaired muco ciliary clearance
- pulmonary lesions cystic fiber
- AIDS merged CARINI’s cystic, coma, respiratory failure
- diaphragm impairment, pneumonia atelectasis
- senile pneumonia, muscular dystrophy,
- decreased muscle function, decreased ventilation lung volumes, impaired gas exchange, alveolar impairment
- sedation, neuro injury, spinal muscular atrophy, etc.
Patients after:
- surgery, tracheotomy, preoperative airway cleaning, coma, spinal cord injury, ventilator dependence
The Clarity Difference...
Accelerate sales
Deliver right first time at the right price to the right customer. Secure access to the local healthcare supply chains.
Maximise speed to market & ROI
with a comprehensive, localised and targeted sales and marketing strategy
Boost profitability
Your product and business growth are in safe hands without unnecessary commercial and supply chain investment
Avoid Compliance Issues
by ensuring your product is fit for the target market – legally and technically

PneuVest - Airway Clearance System
- Clinical practice shows that chest wall oscillation sputum excretion is superior to me chanical oscillation sputum removal
- Automatic operation reduces workload on medical staff
- Safety protection measures, safe, reliable and efficient in the process of sputum excretion treatment
- Ergonomic vest air bag, efficient and safe
- 8-inch HD touch-screen navigation operation, treatment information can be stored for query
- Reduces use of antibiotics and infusion, improves bed turnover rate

PV-100 airway clearance system
technical specification
Description | |
---|---|
Treatment modes | Three modes: regular/gradient/loop |
Pressure | 1-10 gears |
Frequency | 5-20Hz |
Session time | 1-99 minutes |
Interface | 8-inch colour LCD touch screen |
Automatic cough pause | Yes |
Remote one-button stop function | Yes |
Type of vest/chest band | Reusable or single-patient use, optional |
Single-use vest material | PVC, non-woven fabric |
Data saving | Available |
Power cord | Hospital-grade plug |
Main unit dimensions | Height: 27.0cm
Width: 35.5cm
Depth: 35.5cm |
Main unit weight | 14.5kg |
Power supply | 100-240V, AC, 400VA, 50 Hz |
Shipping case dimensions | Height: 48.0cm
Width: 47.5cm
Depth: 46.5cm |
Shipping case weight | 18kg |
Fuse requirement | 2 each, F3.5AL250V φ5X20 |
Operating conditions | Temperature: 5°C to 40°C
Relative humidity: 80% maximum, non-condensing
Atmospheric pressure: 700 mbar to 1060 mbar |
Transport and storage conditions | -20°C (-4°F) to 55° C (131°F)
If the user suspects that the environment conditions for transport and storage have been exceeded, return the unit for service. |
The above specifications are subject to change without further notice.
Lifotronic | HILL-ROM | |
---|---|---|
Model | PV-100 | VEST 205 |
Function | Sputum excretion module | Sputum excretion module |
Operation | True colour liquid touch screen + knob navigation | Knob navigation |
Safety | One button pause function + pressure and frequency automatic adjustment function | Without one button pause function |
Pressure grade | 3-30 MMHG | 1-10 MMHG |
Oscillation frequency | Wider range: 1-20Hz | Less range: 5-20Hz |
Working modes | Common, Cycle, Gradient, Intelligent customisation | Common, Cycle, Gradient, Intelligent customisation |
Screen | 8-inch high-definition touch screen | LED |
Chest ‘V’ airbag design | Yes | No |
Back airbag centre isolated design | Yes | No |
Device Cost | Competitive | Expensive |
Lifotronic advantage summary | 1. 8-inch high-definition touch screen convenient for medical staff to use and has the function of treatment information storage.
2. Automatic cough pause function – ensures the safety of patients during treatment. | 3. With frequency range of 1-20Hz to improve patient tolerance and bring better clinical treatment effect.
4. Ergonomic airbag vest with a professional and efficient safety design to enhance comfort and sputum excretion. |
PneuVest - Airway Clearance System
- Clinical practice shows that chest wall oscillation sputum excretion is superior to me chanical oscillation sputum removal
- Automatic operation reduces workload on medical staff
- Safety protection measures, safe, reliable and efficient in the process of sputum excretion treatment
- Ergonomic vest air bag, efficient and safe
- 8-inch HD touch-screen navigation operation, treatment information can be stored for query
- Reduces use of antibiotics and infusion, improves bed turnover rate